  Datasheet File OCR Text:
 WRA_SP-3W & WRB_SP-3W Series
3W, WIDE INPUT, IAOLATED & REGULATED DUAL/SINGLE OUTPUT DIP DC-DC CONVERTER
multi-country patent protection RoHS FEATURES
Wide (2:1) input range Efficiency up to 82% Short circuit protection(automatic recovery) Operating temperature: -40C to +85C Internal SMD construction 1.5KVDC Isolation Metal shielding package No Heat sink required No external component required Industry standard Pinout MTBF>1,000,000 hours RoHS Compliance
PRODUCT PROGRAM
Part Number WRA0505SP-3W WRA0509SP-3W WRA0512SP-3W WRA0515SP-3W WRB0505SP-3W WRB0509SP-3W WRB0512SP-3W WRB0515SP-3W WRA1205SP-3W WRA1209SP-3W WRA1212SP-3W WRA1215SP-3W WRB1205SP-3W WRB1209SP-3W WRB1212SP-3W WRB1215SP-3W WRB1224SP-3W WRA2405SP-3W WRA2409SP-3W WRA2412SP-3W WRA2415SP-3W WRB2405SP-3W WRB2409SP-3W WRB2412SP-3W WRB2415SP-3W WRB2424SP-3W WRA4805SP-3W WRA4809SP-3W WRA4812SP-3W WRA4815SP-3W WRB4805SP-3W WRB4809SP-3W WRB4812SP-3W WRB4815SP-3W WRB4824SP-3W Input Voltage (VDC) Nominal Range Max* Voltage (VDC) 5 9 12 15 5 9 12 15 5 9 12 15 5 9 12 15 24 5 9 12 15 5 9 12 15 24 5 9 12 15 5 9 12 15 24 Output Current Max 300 166 125 100 600 333 250 200 300 166 125 100 600 333 250 200 125 300 166 125 100 600 333 250 200 125 300 166 125 100 600 333 250 200 125 (mA) Min 30 16 12 10 60 33 25 20 30 16 12 10 60 33 25 20 12 30 16 12 10 60 33 25 20 12 30 16 12 10 60 33 25 20 12 Efficiency (%, Typ) 68 70 72 71 68 70 72 71 74 76 78 79 76 78 80 79 81 78 80 82 81 78 80 82 81 80 78 79 80 81 78 79 80 81 80
5
4.5-9
11
12
9-18
22
APPLICATIONS
The WRB_SP-3W & WRA_SP-3W Series are specially designed for applications where a wide range input voltage power supplies are isolated from the input power supply in a distributed power supply system on a circuit board. These products apply to: 1) Where the voltage of the input power supply is wide range (voltage range: 2:1); 2) Where isolation is necessary between input and output(isolation voltage1500VDC); 3) Where the regulation of the output voltage and the output ripple noise are demanded.
24
18-36
40
48
36-72
80
MODEL SELECTION WRB0512SP-3W
Rated Power Package Style Output Voltage Input Voltage Product Series
*Input voltage can't exceed this value, or will cause the permanent damage. Note: The load shouldn't be less than 10%, otherwise ripple will increase dramatically. Operation under 10% load will not damage the converter; However, they may not meet all specification listed.
OUTPUT SPECIFICATIONS
Item Output power Positive voltage accuracy Negative voltage accuracy Load regulation Line regulation Temperature drift (Vout) Ripple & Noise** Switching frequency Test conditions Refer to product program Refer to recommended circuit Refer to recommended circuit From 10% to 100% load Input voltage from low to high Refer to recommended circuit 20MHz Bandwidth 100% load, nominal input voltage Min 0.3 Typ 1 3 0.5 0.2 75 300 Max Units 3 W 3 5 % 1* 0.5 0.03 %/C 150 mVp-p KHz
MORNSUN Science & Technology co.,Ltd.
Address: 2th floor 6th building, Hangzhou Industrial District, Guangzhou, China Tel: 86-20-38601850 Fax: 86-20-38601272 http://www.mornsun-power.com
*Dual output models unbalanced load: 5%. **Test ripple and noise by "parallel cable" method. See detailed operation instructions at Testing of Power Converter section, application notes.
MORNSUN reserves the copyright
Specifications subject to change without notice.
WRA_SP-3W & WRB_SP-3W
A/1-2008
Page 1 of 2
COMMON SPECIFICATIONS
Item Storage humidity Operating temperature Storage temperature Temp. rise at full load Lead temperature No-load power consumption Isolation voltage Isolation resistance Isolation Capacitance Cooling Short circuit protection Case material MTBF Weight Tested for 1 minute and 1 mA max 1500 Test at 500VDC Input/Output Free air convection Continuous, automatic recovery Aluminium alloy 1000 15 K hours g 1000 100 1.5mm from case for 10 seconds 0.2 -40 -55 15 300 W VDC M pF Test Conditions Min Typ Max 95 85 125 C Units %
Recommended Circuit All the WRA_SP-3W & WRB_SP-3W Series have been tested according to the following recommended testing circuit before leaving factory (Figure 1). This series should be tested under load.
Vin
Ci n
+Vout
DC
DC
0V -Vout
GND Single Output Vin
Cin
+Vout
DC
DC
0V
GND
If
you
(Figure 1) want to further ripple, you
decrease can
the
Note: 1. All specifications measured at TA=25C, humidity<75%, nominal input voltage and rated output load unless otherwise specified. 2.See below recommended circuits for more details.
input/output
increase
capacitance properly or choose capacitors with low ESR. However, the capacitance of the output filter capacitor must be proper. If the capacitance is too big, a startup problem might arise. For every channel of output, provided the safe and reliable operation is ensured, the greatest capacitance of its filter capacitor sees (Table 1). General: Cin: 5V&12V 100F 24V&48V 10F-47F Cout: 10F/100mA Output External Capacitor Table(Table 1) Single Vout Cout Dual Vout Cout (VDC) (uF) (VDC) (uF) 5 1000 5 680 9 12 680 470 330 220 9 12 15 470 330 220 -
TYPICAL CHARACTERISTICS
100
Operating Temp.( C )
OUTLINE DIMENSIONS& PIN CONNECTIONS
3.88 (0.153) First Angle Projection 35.00 (1.378) FOOTPRINT DETAILS
2 3
15 24
7.62 7.62 (0.300)(0.300) 23.00(0.905)
7.62 (0.300)
1
(Bottom View)
4
5
Pin 1 2 3 4 5
Single Vin GND 0V No Pin +Vo
Dual Vin GND -Vo 0V +Vo
Input Current When it is used in unregulated power supply, be sure that the fluctuating range of the power supply and the rippled voltage do not exceed the module standard. Input current of power supply should afford the startup current of this kind of DC/DC module. (Figure 2) General: Ip 1.4*Iin-max
2.90 (0.11 4)
29.21(1.150)
8.50 (0.335)
4.10 (0.161)
Input Current(A)
(Side View)
0.50 (0.020)
Note: Unit:mm(inch ) Pin diameter:0.80mm(0.031inch ) Pin diameter tolerances: 0.05mm( 0.002inch) General to lerances: 0.25mm( 0.010inch)
Ip
APPLICATION NOTE
Requirement on output load In order to ensure the product operate efficiently and reliably, in addition to a max load (namely full load), a minimum load is specified for this kind of DC/DC converter. Make sure the specified range of input voltage is not exceeded, the minimum output load no less than 10% load. If the actual load is less than the specified minimum load, the output ripple may increase sharply while its efficiency and reliability will reduce greatly. If the actual output power is very small, please add an appropriate resistor as extra loading, or contact our company for other lower output power products.
Input Voltage Range
Input Voltage (V)
No parallel connection or plug and play.
MORNSUN reserves the copyright
Specifications subject to change without notice.
WRA_SP-3W & WRB_SP-3W
A/1-2008
Page 2 of 2


▲Up To Search▲   

 
Price & Availability of WRA0515SP-3W

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X